The laboratory meets the requirements in

NS-EN ISO/IEC 17025:2017




Accreditation includes:

Calibration and Measurement Capabilities (CMC)

The administrative / geographical unit:
Kiwa AS
Bleivassvegen 28B,
5347 Ågotnes



Permanent facility K01 Electrical quantities

Resistance (Dekade resistors and fixed resistors)

Range
Uncertainty (k=2)
Range
0 - 12 Ω
Uncertainty (k=2)
10ppm x R + 30µΩ
Range
12 - 120 Ω
Uncertainty (k=2)
7,0ppm x R + 80 µΩ
Range
120 - 1200 Ω
Uncertainty (k=2)
8,0ppm x R + 80 µΩ
Range
1,2 - 12 kΩ
Uncertainty (k=2)
6,2ppm x R
Range
12 - 120 kΩ
Uncertainty (k=2)
10ppm x R
Range
120 - 1200 kΩ
Uncertainty (k=2)
13ppm x R
Range
1,2 - 12 MΩ
Uncertainty (k=2)
36ppm x R
Range
12 - 120 MΩ
Uncertainty (k=2)
500ppm x R

Remarks/ref. to internal procedure: KH 2-9-1 AC, DC resistance (by measurement), (​​R = measured value)

Resistance

Range
Uncertainty (k=2)
Range
0,2 - 0,9 Ω
Uncertainty (k=2)
3,5ppm x R
Range
0,9 - 1,1 Ω
Uncertainty (k=2)
2,1ppm x R
Range
1,1 - 3 Ω
Uncertainty (k=2)
2,5ppm x R
Range
3 - 9 Ω
Uncertainty (k=2)
3,7ppm x R
Range
9 - 11 Ω
Uncertainty (k=2)
3,1ppm x R
Range
11 - 30 Ω
Uncertainty (k=2)
3,4ppm x R
Range
30 - 90 Ω
Uncertainty (k=2)
2,1ppm x R
Range
90 - 110 Ω
Uncertainty (k=2)
1,6ppm x R
Range
110 - 300 Ω
Uncertainty (k=2)
2,1ppm x R
Range
300 - 900 Ω
Uncertainty (k=2)
3,4ppm x R
Range
900 - 1100 Ω
Uncertainty (k=2)
3,0ppm x R
Range
1,1 - 3 kΩ
Uncertainty (k=2)
3,4ppm x R
Range
3 - 9 kΩ
Uncertainty (k=2)
2,5ppm x R
Range
9 - 11 kΩ
Uncertainty (k=2)
2,1ppm x R
Range
11 - 30 kΩ
Uncertainty (k=2)
3,5ppm x R
Range
30 - 90 kΩ
Uncertainty (k=2)
4,0ppm x R
Range
90 - 110 kΩ
Uncertainty (k=2)
3,5ppm x R

Remarks/ref. to internal procedure: KH-2-9-1 BB, DC resistance (by measurement), (​​R = measured value)

DC- Voltage

Range
Uncertainty (k=2)
Range
0 V
Uncertainty (k=2)
50 nV (short)
Kortslutning
Range
0 mV - 130 mV
Uncertainty (k=2)
0,9 µV
Range
130 mV - 500 mV
Uncertainty (k=2)
6,9ppm x U
Range
500 mV - 2,2 mV
Uncertainty (k=2)
4,4ppm x U
Range
2,2 V - 11 V
Uncertainty (k=2)
3,4ppm x U
Range
11 V - 22 V
Uncertainty (k=2)
3,7ppm x U
Range
22 V - 220 V
Uncertainty (k=2)
4,0ppm x U
Range
220 V - 1100 V
Uncertainty (k=2)
4,0ppm x U

Remarks/ref. to internal procedure: KH-S 2-9-1-S, DC voltage (as the source), (​​U = measured value)

DC Power

Range
Uncertainty (k=2)
Range
0 A (Open)
Uncertainty (k=2)
0,5 nA
Range
0 µA - 220 µA
Uncertainty (k=2)
14ppm x I + 4 nA
Range
220 µA - 2,2 mA
Uncertainty (k=2)
13ppm x I
Range
2,2 mA - 22 mA
Uncertainty (k=2)
12ppm x I
Range
22 mA - 100 mA
Uncertainty (k=2)
12ppm x I
Range
100 mA - 220 mA
Uncertainty (k=2)
14ppm x I
Range
220 mA - 1 mA
Uncertainty (k=2)
16ppm x I
Range
1 A - 2,2 A
Uncertainty (k=2)
32ppm x I
Range
2,2 A - 11A
Uncertainty (k=2)
330ppm x I

Remarks/ref. to internal procedure: KH 2-9-1-T, DC power (as the source), (​​I = measured value)

DC Voltage

Range
Uncertainty (k=2)
Range
0 - 0,12 V
Uncertainty (k=2)
6,4ppm x U + 0,32 µV
Range
0,12 - 1,2 V
Uncertainty (k=2)
3,4ppm x U + 0,6 µV
Range
1,2 - 12 V
Uncertainty (k=2)
2,9ppm x U + 0,9 µV
Range
12 - 120 V
Uncertainty (k=2)
5,3ppm x U + 30uV
Range
120 - 450 V
Uncertainty (k=2)
9,0ppm x U
Range
450 - 700 V
Uncertainty (k=2)
13ppm x U
Range
700 - 1000 V
Uncertainty (k=2)
17ppm x U
Range
Uncertainty (k=2)

Remarks/ref. to internal procedure: KH-2-9-1-AP, DC voltage (by measurement), (​​U = measured value)

AC voltage (as the source)

Range
Uncertainty (k=2)
Range
0,22mV - 2,2mV:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
0,30% x U + 4,5 µV
Range
20 - 40Hz
Uncertainty (k=2)
0,30% x U + 4,5 µV
Range
40 - 20000Hz
Uncertainty (k=2)
0,29% x U + 4,5 µV
Range
20 - 50kHz
Uncertainty (k=2)
0,30% x U + 4,5 µV
Range
50 - 100kHz
Uncertainty (k=2)
0,32% x U + 7,0 µV
Range
100 - 300kHz
Uncertainty (k=2)
0,60% x U + 13 µV
Range
300 - 500kHz
Uncertainty (k=2)
1,1% x U + 25 µV
Range
500 - 1000kHz
Uncertainty (k=2)
1,4% x U + 25 µV
Range
2,2mV - 22mV:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
660ppm x U + 5,0 µV
Range
20 - 40Hz
Uncertainty (k=2)
470ppm x U + 5,0 µV
Range
40 - 20000Hz
Uncertainty (k=2)
510ppm x U + 5,0 µV
Range
20 - 50kHz
Uncertainty (k=2)
600ppm x U + 5,0 µV
Range
50 - 100kHz
Uncertainty (k=2)
0,11% x U + 7,0 µV
Range
100 - 300kHz
Uncertainty (k=2)
0,16% x U + 12 µV
Range
300 - 500kHz
Uncertainty (k=2)
0,30% x U + 25 µV
Range
500 - 1000kHz
Uncertainty (k=2)
0,73% x U + 25 µV
Range
22mV - 200mV:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
520ppm x U + 13 µV
Range
20 - 40Hz
Uncertainty (k=2)
240ppm x U + 8,0 µV
Range
40 - 20000Hz
Uncertainty (k=2)
160ppm x U + 8,0 µV
Range
20 - 50kHz
Uncertainty (k=2)
310ppm x U + 8,0 µV
Range
50 - 100kHz
Uncertainty (k=2)
770ppm x U + 8,0 µV
Range
100 - 300kHz
Uncertainty (k=2)
0,12% x U + 25 µV
Range
300 - 500kHz
Uncertainty (k=2)
0,22% x U + 35 µV
Range
500 - 1000kHz
Uncertainty (k=2)
0,66% x U + 80 µV
Range
0,22V - 2,2V:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
470ppm x U + 80 µV
Range
20 - 40Hz
Uncertainty (k=2)
190ppm x U + 25 µV
Range
40 - 20000Hz
Uncertainty (k=2)
90ppm x U + 6,0 µV
Range
20 - 50kHz
Uncertainty (k=2)
150ppm x U + 16 µV
Range
50 - 100kHz
Uncertainty (k=2)
260ppm x U + 70 µV
Range
100 - 300kHz
Uncertainty (k=2)
560ppm x U + 130 µV
Range
300 - 500kHz
Uncertainty (k=2)
0,15% x U + 350 µV
Range
500 - 1000kHz
Uncertainty (k=2)
0,38% x U + 850 µV
Range
2,2V - 22V:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
470ppm x U + 800 µV
Range
20 - 40Hz
Uncertainty (k=2)
190ppm x U + 250 µV
Range
40 - 20000Hz
Uncertainty (k=2)
110ppm x U + 60 µV
Range
20 - 50kHz
Uncertainty (k=2)
140ppm x U + 160 µV
Range
50 - 100kHz
Uncertainty (k=2)
260ppm x U + 350 µV
Range
100 - 300kHz
Uncertainty (k=2)
620ppm x U + 1,5 mV
Range
300 - 500kHz
Uncertainty (k=2)
0,16% x U + 4,3 mV
Range
500 - 1000kHz
Uncertainty (k=2)
0,40% x U + 8,5 mV
Range
22V - 220V:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
470ppm x U + 8,0 mV
Range
20 - 40Hz
Uncertainty (k=2)
190ppm x U + 2,5 mV
* Spenningen U er
Range
40 - 20000Hz
Uncertainty (k=2)
110ppm x U + 800 µV
begrenset slik at
Range
20 - 50kHz
Uncertainty (k=2)
210ppm x U + 3,5 mV
fxU ikke er mer enn:
Range
50 - 100kHz
Uncertainty (k=2)
480ppm x U + 8,0 mV
2,2 x 10-7 V x Hz
Range
220V - 1100V:
Uncertainty (k=2)
Range
40 - 1000Hz
Uncertainty (k=2)
130ppm x U + 4,0 mV
Range
1 - 20kHz
Uncertainty (k=2)
200ppm x U + 6,0 mV

Remarks/ref. to internal procedure: Procedure: KH-U 2-9-1, AC voltage (the source), (​​U = nominal value)

AC power (as the source)

Range
Uncertainty (k=2)
Range
9uA - 220uA:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
650ppm x I + 25 nA
Range
20 - 40Hz
Uncertainty (k=2)
350ppm x I + 20 nA
Range
40 - 1000Hz
Uncertainty (k=2)
190ppm x I + 16 nA
Range
1 - 5kHz
Uncertainty (k=2)
0,10% x I + 40 nA
Range
5 - 10kHz
Uncertainty (k=2)
0,27% x I + 80 nA
Range
0,22mA - 2,2mA:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
650ppm x I + 40 nA
Range
20 - 40Hz
Uncertainty (k=2)
340ppm x I + 35 nA
Range
40 - 1000Hz
Uncertainty (k=2)
180ppm x I + 35 nA
Range
1 - 5kHz
Uncertainty (k=2)
880ppm x I + 400 nA
Range
5 - 10kHz
Uncertainty (k=2)
0,20% x I + 800 nA
Range
2,2mA - 22mA:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
610ppm x I + 400 nA
Range
20 - 40Hz
Uncertainty (k=2)
330ppm x I + 350 nA
Range
40 - 1000Hz
Uncertainty (k=2)
160ppm x I + 350 nA
Range
1 - 5kHz
Uncertainty (k=2)
0,13% x I + 4,0 uA
Range
5 - 10kHzz
Uncertainty (k=2)
0,27% x I + 8,0 uA
Range
22mA - 220mA:
Uncertainty (k=2)
Range
10 - 20Hz
Uncertainty (k=2)
610ppm x I + 4,0 uA
Range
20 - 40Hz
Uncertainty (k=2)
330ppm x I + 3,5 uA
Range
40 - 1000Hz
Uncertainty (k=2)
160ppm x I + 3,5 uA
Range
1 - 5kHz
Uncertainty (k=2)
0,13% x I + 40 uA
Range
5 - 10kHz
Uncertainty (k=2)
0,27% x I + 80 uA
Range
0,22A - 2,2A:
Uncertainty (k=2)
Range
40 - 1000Hz
Uncertainty (k=2)
570ppm x I + 35 uA
Range
1 - 5kHz
Uncertainty (k=2)
0,41% x I + 80 uA
Range
5 - 10kHz
Uncertainty (k=2)
1,5% x I + 160 uA
Range
2,2A - 11A:
Uncertainty (k=2)
Range
40 - 1000Hz
Uncertainty (k=2)
500ppm x I + 170 uA
Range
1 - 5kHz
Uncertainty (k=2)
0,23% x I + 380 uA
Range
5 - 10kHz
Uncertainty (k=2)
0,78% x I + 580 uA

Remarks/ref. to internal procedure: KH 2-9-1-W AC power (as the source), (​​I = nominal value)

DC Power

Range
Uncertainty (k=2)
Range
0 mA - 0,1 mA
Uncertainty (k=2)
3,8nA
Range
0,1 mA - 0,5 mA
Uncertainty (k=2)
6,2nA
Range
0,5 mA - 1,2 mA
Uncertainty (k=2)
10nA
Range
1,2 mA - 2,2 mA
Uncertainty (k=2)
15nA
Range
2,2 mA - 5,0 mA
Uncertainty (k=2)
25nA
Range
5,0 mA - 7,0 mA
Uncertainty (k=2)
33nA
Range
7,0 mA - 12 mA
Uncertainty (k=2)
44nA
Range
12 mA - 14 mA
Uncertainty (k=2)
51nA
Range
14 mA - 22 mA
Uncertainty (k=2)
75nA
Range
22 mA - 40 mA
Uncertainty (k=2)
0,13µA
Range
40 mA - 70 mA
Uncertainty (k=2)
0,22µA
Range
70 mA - 100 mA
Uncertainty (k=2)
0,31µA
Range
100 mA - 120 mA
Uncertainty (k=2)
1,0µA
Range
0,12 A - 0,22 A
Uncertainty (k=2)
1,5µA
Range
0,22 A - 0,50 A
Uncertainty (k=2)
3,0µA
Range
0,50 A - 1,0 A
Uncertainty (k=2)
130µA
Range
1 A - 6 A
Uncertainty (k=2)
0,60mA
Range
6 A - 9,9 A
Uncertainty (k=2)
1,0mA
Range
9,9 A - 10,1 A
Uncertainty (k=2)
0,8mA
Range
10,1 A - 19,9 A
Uncertainty (k=2)
8,0mA
Range
19,9 A - 20 A
Uncertainty (k=2)
1,5mA
Range
20 A - 30 A
Uncertainty (k=2)
8,0mA
Range
30 A - 50 A
Uncertainty (k=2)
38mA

Remarks/ref. to internal procedure: KH-2-9-1-AN, DC power (by measurement), (​​I = measured value)

DC resistance (as sources)

Range
Uncertainty (k=2)
Range
0 Ω
Uncertainty (k=2)
5,0 µΩ
Range
0,01 Ω
Uncertainty (k=2)
0,9 µΩ
Range
0,02 Ω
Uncertainty (k=2)
1,9 µΩ
Range
1 Ω
Uncertainty (k=2)
3,0 µΩ
Range
1,9 Ω
Uncertainty (k=2)
38 µΩ
Range
10 Ω
Uncertainty (k=2)
30 µΩ
Range
19 Ω
Uncertainty (k=2)
140 µΩ
Range
100 Ω
Uncertainty (k=2)
210 µΩ
Range
190 Ω
Uncertainty (k=2)
1,3 mΩ
Range
1000 Ω
Uncertainty (k=2)
3,0 mΩ
Range
1900 Ω
Uncertainty (k=2)
11 mΩ
Range
10 kΩ
Uncertainty (k=2)
21 mΩ
Range
19 kΩ
Uncertainty (k=2)
130 mΩ
Range
100 kΩ
Uncertainty (k=2)
220 mΩ
Range
190 kΩ
Uncertainty (k=2)
1,6 Ω
Range
1 MΩ
Uncertainty (k=2)
7 Ω
Range
1,9 MΩ
Uncertainty (k=2)
28 Ω
Range
10 MΩ
Uncertainty (k=2)
170 Ω
Range
19 MΩ
Uncertainty (k=2)
420 Ω
Range
100 MΩ
Uncertainty (k=2)
3,6 kΩ

Remarks/ref. to internal procedure: KH-2-9-1
Permanent facility K03 Time and frequency

Frequency (measurement)

Range
Uncertainty (k=2)
Range
1 MHz
Uncertainty (k=2)
7,5 x 10-12 x f
Range
5 MHz
Uncertainty (k=2)
7,5 x 10-12 x f
Range
10 MHz
Uncertainty (k=2)
7,5 x 10-12 x f

Remarks/ref. to internal procedure: KH 2-9-1 AK

Frequency (measurement with frequency counter)

Range
Uncertainty (k=2)
Range
1 Hz til/to 10 Hz
Uncertainty (k=2)
1,0 x 10-8 x f
Square Sign
Range
10 Hz til/to 1,3 GHz
Uncertainty (k=2)
1,0 x 10-9 x f
Square Sign
Range
1 Hz til/to 2 Hz
Uncertainty (k=2)
1,0 x 10-6 x f
Sine Signal
Range
2 Hz til/to 20 Hz
Uncertainty (k=2)
1,0 x 10-8 x f
Sine Signal
Range
20 Hz til/to 1,3 GHz
Uncertainty (k=2)
1,0 x 10-9 x f
Sine Signal

Remarks/ref. to internal procedure: KH 2-9-1 AK

Frequency (generation)

Range
Uncertainty (k=2)
Range
1 µHz til/to 4 GHz
Uncertainty (k=2)
1,0 x 10-10 x f

Remarks/ref. to internal procedure: KH 2-9-1 AH
Permanent facility K05 Mechanical quantities

Mass (weight)

Range
Uncertainty (k=2)
Range
Fra 0,001 g til og med 20 g
Uncertainty (k=2)
0,10 mg
Range
Fra 20 g til og med 205 g
Uncertainty (k=2)
0,16 mg
Range
Fra 205 g til og med 500 g
Uncertainty (k=2)
0,4 mg
Range
Fra 500 g til og med 1100 g
Uncertainty (k=2)
0,5 mg
Range
Fra 1,1 kg til og med 10 kg
Uncertainty (k=2)
25 mg
Range
Fra 10 kg til og med 20 kg
Uncertainty (k=2)
60 mg

Remarks/ref. to internal procedure: KH 2-9-1 AV, ID-1800

Pressure (gauge)

Range
Uncertainty (k=2)
Range
-100 kPa til/to 0 hPa
Uncertainty (k=2)
7,8 til/to 0,25 Pa
Range
0 hPa til/to 100 kPa
Uncertainty (k=2)
0,25 til/to 7 Pa
Range
100 kPa til/to 2,5MPa
Uncertainty (k=2)
7 til/to 130 Pa
Range
2,5 MPa til/to 25 MPa
Uncertainty (k=2)
0,13 til/to 1,2 kPa
Range
25 MPa til/to 100 MPa
Uncertainty (k=2)
1,2 til/to 5,6 kPa
Range
100 MPa til/to 250 MPa
Uncertainty (k=2)
250 kPa til/to 500 kPa

Remarks/ref. to internal procedure: KH 2-9-1 A, KH 2-9-1 AG

Pressure (abs)

Range
Uncertainty (k=2)
Range
0 hPa til/to 1200 hPa
Uncertainty (k=2)
3,5 Pa til/to 10 Pa
Range
1200 hPa til/to 200 kPa
Uncertainty (k=2)
10 Pa til/to 17 Pa
Range
200 kPa til/to 2,6 Mpa
Uncertainty (k=2)
17 Pa til/to 140 Pa
Range
2,6 MPa til/to 25 Mpa
Uncertainty (k=2)
0,14 kPa til/to 1,2 kPa
Range
25 MPa til/to 100 Mpa
Uncertainty (k=2)
1,2 kPa til/to 5,6 kPa
Range
Uncertainty (k=2)

Remarks/ref. to internal procedure: KH 2-9-1 A, KH 2-9-1 AG

Piston Area oil

Range
Uncertainty (k=2)
Range
40 MPa til/to 100 Mpa
Uncertainty (k=2)
55 ppm
Range
Uncertainty (k=2)
Range
Uncertainty (k=2)
Range
Uncertainty (k=2)
Range
Uncertainty (k=2)

Remarks/ref. to internal procedure: KH 2-9-1 G

Pressure (diff)

Range
Uncertainty (k=2)
Range
0 Mpa til/to 0,4 Mpa
Uncertainty (k=2)
2 Pa til/to 24 Pa
Range
0,4 Mpa til/to 20 Mpa
Uncertainty (k=2)
24 Pa til/to 970 Pa

Remarks/ref. to internal procedure: KH 2-9-1 A, KH 2-9-1 AG

Piston Area gas

Range
Uncertainty (k=2)
Range
15 hPa til/to 100 kPa
Uncertainty (k=2)
75 ppm
Range
100 kPa til/to 2,5MPa
Uncertainty (k=2)
55 ppm
Range
2,5 MPa til/to 25 Mpa
Uncertainty (k=2)
48 ppm
Range
Uncertainty (k=2)
Range
Uncertainty (k=2)

Remarks/ref. to internal procedure: KH 2-9-1 AE
Permanent facility K07 Fluid quantities

Density of gas (kg/m3 in the pressure range)

Range
Uncertainty (k=2)
Range
1 kg/m3 til/to130 kg/m3
Uncertainty (k=2)
0,5 g/m3 + 0,028 % av avlest
Range
130 kg/m3 til/to 300 kg/m3
Uncertainty (k=2)
0,052 % av avlest

Remarks/ref. to internal procedure: KH 2-9-1 Q (ID-3695) og KH 2-9-1 M (ID-1804), 270 to 350 ° K, Nitrogen

Density of liquids

Range
Uncertainty (k=2)
Range
650 kg/m3 til/to 1350 kg/m3
Uncertainty (k=2)
80 g/m3 til/to 100 g/m3

Remarks/ref. to internal procedure: KH 2-9-1 N and V, 10 °C to 40 °C
Permanent facility K10 Temperature, humidity and thermophysical properties

Direct reading instruments

Range
Uncertainty (k=2)
Range
-80 °C til/to -50 °C
Uncertainty (k=2)
20mK
Range
-50 °C til/to -10 °C
Uncertainty (k=2)
15 mK
Range
-10 °C til/to +100 °C
Uncertainty (k=2)
10mK
Range
+100 °C til/to +200 °C
Uncertainty (k=2)
15mK
Range
+200 °C til/to +280 °C
Uncertainty (k=2)
17mK

Remarks/ref. to internal procedure: KH 2-9-1 AW

Resistance thermometers

Range
Uncertainty (k=2)
Range
-80 °C til/to -50 °C
Uncertainty (k=2)
20 mK
Range
-50 °C til/to -10 °C
Uncertainty (k=2)
15 mK
Range
-10 °C til/to+100 °C
Uncertainty (k=2)
10 mK
Range
+100 °C til/to +200 °C
Uncertainty (k=2)
15 mK
Range
+200 °C til/to +280 °C
Uncertainty (k=2)
17 mK

Remarks/ref. to internal procedure: KH 2-9-1 F

Temperature transmitters

Range
Uncertainty (k=2)
Range
-80 °C til/to -50 °C
Uncertainty (k=2)
30mK
Range
-50 °C til/to -10 °C
Uncertainty (k=2)
25mK
Range
-10 °C til/to 100 °C
Uncertainty (k=2)
20mK
Range
100 °C til/to 280 °C
Uncertainty (k=2)
25mK

Remarks/ref. to internal procedure: KH 2-9-1 AY
The administrative / geographical unit:
Kiwa AS
Kabelgaten 2
0580 Oslo



Field testing laboratory K05 Mechanical quantities

Brake pressure sensor. Manometer

Range
Uncertainty (k=2)
Range
0 bar til/to 16 bar
Uncertainty (k=2)
± 0,08 bar

Remarks/ref. to internal procedure: ID-1989 Analog reading

Brake pressure sensor. Manometer

Range
Uncertainty (k=2)
Range
0 bar til/to 16 bar
Uncertainty (k=2)
± 0,06 bar

Remarks/ref. to internal procedure: ID-1989 Digital reading

Deceleration measurement

Range
Uncertainty (k=2)
Range
0-100 %g
Uncertainty (k=2)
± 1,2%g v/30%g = 0,12 m/s2 ± 1.2%g v/75%g = 0,12 m/s2
Bowmonk (analog)
Range
0-100 %g
Uncertainty (k=2)
± 1,3%g v/28%g = 0,13 m/s2 ± 1,3%g v/60%g = 0,13 m/s2
Bowmonk (digital)
Range
0-100 %g
Uncertainty (k=2)
±0,56%g v/28%g = 0,06 m/s2 ±0,57%g v/60%g = 0,06 m/s2
MotoMeter
Range
0-6,00 m/s2
Uncertainty (k=2)
±0,02 m/s2 v/2,8 m/s2 ±0,03 m/s2 v/6,0 m/s2
MaHa (digital)

Remarks/ref. to internal procedure: ID-1990

Brake tester - Dead weight

Range
Uncertainty (k=2)
Range
1 kN til 6 kN (personbil)
Uncertainty (k=2)
± 0,024 kN ved 1 kN
Range
Uncertainty (k=2)
± 0,061 kN ved 8 kN

Remarks/ref. to internal procedure: ID-1986

Brake tester - Load cell

Range
Uncertainty (k=2)
Range
1 kN til 8 kN (personbil)
Uncertainty (k=2)
± 0,024 kN ved 1 kN
Range
Uncertainty (k=2)
± 0,063 kN ved 6 kN

Remarks/ref. to internal procedure: ID-1986
Field testing laboratory K07 Fluid quantities

Exhaust gases analyser - Hydrocarbons

Range
Uncertainty (k=2)
Range
25 - 1750 vol ppm
Uncertainty (k=2)
± 7 vol ppm ved 25 vol ppm
Range
Uncertainty (k=2)
± 50 vol ppm ved 1750 vol ppm

Remarks/ref. to internal procedure: ID-1985 Calibrations with two gas concentrations

Exhaust gases analyser - Carbon dioxide (CO2)

Range
Uncertainty (k=2)
Range
6,5 - 14,00 vol%
Uncertainty (k=2)
± 0,07 vol% v/ 6,5 vol% ± 0,15 vol% v/ 14,0 vol%

Remarks/ref. to internal procedure: ID-1985 Calibration with two gas concentrations

Exhaust gases analyser - Carbon dioxide (CO)

Range
Uncertainty (k=2)
Range
0,5 - 4,0 vol%
Uncertainty (k=2)
± 0,02 vol% v/ 0,5 vol% ± 0,04 vol% v/ 4,0 vol%

Remarks/ref. to internal procedure: ID-1985 Calibration with two gas concentrations

Diesel smoke meter - k-value

Range
Uncertainty (k=2)
Range
0,8 - 4,0 m-1
Uncertainty (k=2)
± 0,09 m-1 v/ 0,8 m-1 ± 0,10 m-1 v/ 3,7 m-1

Remarks/ref. to internal procedure: ID-1991 Calibration with two or more filters
Field testing laboratory K08 Optical quantities

Headlamp beam tester

Range
Uncertainty (k=2)
Range
0 - 40 mm/m nedvinkling
Uncertainty (k=2)
± 1,2 mm/m

Remarks/ref. to internal procedure: ID-1993