You are here:
Norwegian accreditation

Accreditation scope for

TEST 266

Bergen kommune

Bergen Vann - Vannlaboratoriet

Spelhaugen 22
5147 Fyllingsdalen

Telephone: 55 56 78 64 / 948 26 782 / 920 65 798
E-mail: vannlaboratoriet@bergen.kommune.no
Internet: http://www.bergenvann.com
The laboratory meets the requirements in

NS-EN ISO/IEC 17025:2017


*Partially suspended (Voluntary or involuntary)


Accreditation includes:
The administrative / geographical unit:
Bergen Vann - Vannlaboratoriet
Spelhaugen 22
5147 Fyllingsdalen



Permanent facility
P12 Chemical analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Chemical oxygen demand index (COD)
Reference standard
ISO 15705
Internal method identity
1046
Comment
Oxidation with dicromat
Object
Waste water and superficies water
Parameter
Determination of biochemical oxygen demand after 5 days (BOD5)
Reference standard
NS-EN ISO 5815-1
Internal method identity
1045
Comment
Dilution and seeding method with allylthiourea addition
Object
Waste water, sea water, superficies water and pure water
Parameter
Determination of suspended solids
Reference standard
NS-EN 872
Internal method identity
1047
Comment
Filtration
Object
Pure water
Parameter
UV transmission
Reference standard
NS 9462
Internal method identity
1050
Comment
Analysis robot
Object
Pure water and pool water
Parameter
Colour
Reference standard
NS-EN ISO 7887
Internal method identity
1050
Comment
Robot analyzer. Method C.
Object
Clean water and pool water
Parameter
pH
Reference standard
NS-EN ISO 10523
Internal method identity
1050
Comment
Object
Clean water and pool water
Parameter
Determination of turbidity
Reference standard
NS-EN ISO 7027-1
Internal method identity
1048
Comment
Spectophotometry Quantitative.
Object
Clean water and seawater
Parameter
Electrical conductivity
Reference standard
NS-ISO 7888
Internal method identity
1050
Comment
Robot analyzer
P16 Microbiological analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
All types of water
Parameter
Culturable microorganisms
Reference standard
NS-EN ISO 6222
Internal method identity
1039
Comment
Plate count at 22 C and 36 C
Object
All types of water
Parameter
Enumeration of Clostridium perfringens
Reference standard
NS-EN ISO 14189
Internal method identity
1038
Comment
Method using membrane filtration (ISO 14189:2013)
Object
Pool water and sea water
Parameter
Thermotolerant coliform bacteria and presumptive E.coli
Reference standard
NS 4792
Internal method identity
1042
Comment
MF-method. Restricted to water not tested according to the European water directive.
Object
Pool water and pure water
Parameter
Detection and enumeration Pseudomonas aeruginosa
Reference standard
NS-EN ISO 16266
Internal method identity
1037
Comment
MF-method.
Object
Clean water, pool water and seawater
Parameter
Enumeration of Intestinal Enterococci
Reference standard
ISO 7899-2
Internal method identity
1040
Comment
Object
Pure water, sea water, pool water and waste water
Parameter
Enumeration of E. coli and coliform organisms
Reference standard
ISO 9308-2
Internal method identity
1041
Comment
MPN-method (Colilert).
Object
Waters with low bacterial background flora
Parameter
Enumeration of Escherichia coli and coliform bacteria
Reference standard
NS-EN ISO 9308-1/A1
Internal method identity
1036
Comment
Membrane filtration