The administrative / geographical unit:
Alvim renseanlegg
Fredrikstadveien 71, 1722 Sarpsborg
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe
The administrative / geographical unit:
Bodal renseanlegg
Rådhusveien 8
1890 Rakkestad
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe
The administrative / geographical unit:
Bommen Renseanlegg
Idrettsparkveien 20
1870 Ørje
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe
The administrative / geographical unit:
Frogn Renseanlegg
Elleveien 60, 1440 Drøbak
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water height
Reference standard
Internal method
Internal method identity
70
Comment
Channel measurement in free water table
The administrative / geographical unit:
Fuglevik renseanlegg
Båthavnveien 50, 1570 Dilling
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe
The administrative / geographical unit:
Kambo rensenanlegg
Møllebakken, 1538 Moss
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe
The administrative / geographical unit:
Mysen Renseanlegg
Sponesveien 10
1850 Mysen
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the inlet and outlet from open water systems.
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe
The administrative / geographical unit:
Remmendalen renseanlegg
Refneveien 33, 1771 Halden
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe
The administrative / geographical unit:
Revaug renseanlegg
Engerveien 38, 1815 Askim
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water height
Reference standard
Internal method
Internal method identity
70
Comment
Channel measurement in free water table
Parameter
Water flow in sewage treatment plants based on water height
Reference standard
Internal method
Internal method identity
70
Comment
Overflow measurement in a free water table
The administrative / geographical unit:
Øra renseanlegg
Habornveien 61
1630 GAMLE FREDRIKSTAD
Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
23
Comment
Method based on automatic sampling volume proportional samples from the open water systems.
Parameter
Samples for analysis of Hg and DEHP
Reference standard
Internal Method
Internal method identity
24
Comment
Method based on the eligible sample (manual sampling).
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Parameter
Water flow in sewage treatment plants based on water height
Reference standard
Internal method
Internal method identity
70
Comment
Channel measurement in free water table
Parameter
Water flow in sewage treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
70
Comment
Electromagnetic measurement in a closed pipe