You are here:
Norwegian accreditation

Accreditation scope for

TEST 037

Labora AS

Klinkerveien 8
8006 Bodø

Telephone: 75 56 63 00
E-mail: firmapost@labora.no
Internet: http://www.labora.no
The laboratory meets the requirements in

NS-EN ISO/IEC 17025:2017




Accreditation includes:
The administrative / geographical unit:
Ble Fjellskog avløpsrenseanlegg
Dyrebu fjellgrend nr. 86, 3622 Svene (koordinater: 59.7691739, 9.4719593)


Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
The administrative / geographical unit:
Brokke renseanlegg
Suleskarvegen ved Brokke alpinsenter i Valle kommune (koordinater: 59.096546, 7.453139)


Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
The administrative / geographical unit:
Hammarvika renseanlegg
Fredensborgveien 3
8003 Bodø



Permanent facility
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
Sampling in permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
The administrative / geographical unit:
Kjøtteinståa renseanlegg
Kjøtteinsvegen 223
5411 Stord



Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
The administrative / geographical unit:
Kulstad renseanlegg
Leira 25
8665 Mosjøen



Permanent facility
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
Sampling in permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
The administrative / geographical unit:
Kvalvikodden renseanlegg
Kvalvikodden gnr 32 bnr 942
8012 Bodø



Permanent facility
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
Sampling in permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
The administrative / geographical unit:
Labora AS. Bodø
Klinkerveien 8
8006 Bodø



Permanent facility
P12 Chemical analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Wastewater
Parameter
Chemical oxygen demand index (COD)
Reference standard
ISO 15705
Internal method identity
23
Comment
Digestion/photometry
Object
Waste water and pure water
Parameter
Determination of suspended solids
Reference standard
NS-EN 872
Internal method identity
24
Comment
Object
Fish, fish products and fish feed
Parameter
Fat
Reference standard
Internal method
Internal method identity
203
Comment
Method based on NS 9402
Object
Food
Parameter
Moisture and residue
Reference standard
Internal method
Internal method identity
201
Comment
Method based on NMKL 23 (1991)
Object
Food
Parameter
Ashes
Reference standard
Internal method
Internal method identity
201
Comment
Method based on NMKL 173 (2005)
Object
Clean water
Parameter
Dissolved chloride, fluoride, sulfate and nitrate
Reference standard
NS-EN ISO 10304-1
Internal method identity
16
Comment
Ion chromatrography
Object
Clean water
Parameter
Na K
Reference standard
NS 4775
Internal method identity
52 53
Comment
AAS-flame. With ref to NS 4770
Object
Clean water
Parameter
Fe Zn
Reference standard
NS 4773
Internal method identity
61 67
Comment
AAS-flame. With ref to NS 4770
Object
Clean water
Parameter
Mn Cu Al
Reference standard
NS-EN ISO 15586
Internal method identity
62 64 76
Comment
AAS graphite furnace - trace levels
Object
Clean water, wastewater
Parameter
Ammonium nitrogen
Reference standard
NS-EN ISO 11732
Internal method identity
20
Comment
Method by flow analysis (CFA and FIA) and spectrometric detection (ISO 11732:2005)
Object
Clean water and wastewater
Parameter
Orthophosphate
Reference standard
NS-EN ISO 15681-2
Internal method identity
21
Comment
Flow analysis (FIA and CFA) - Part 2: Method by continuous flow analysis (CFA)
Object
Clean water and wastewater
Parameter
Determination of the sum of nitrite-nitrogen and nitrate-nitrogen
Reference standard
NS 4745
Internal method identity
17
Comment
Automated method
Object
Clean water and wastewater
Parameter
Total phosphorus
Reference standard
Internal method
Internal method identity
22
Comment
Method based on modified NS-EN ISO 6878, automated analysis
Object
Pure water and pool water
Parameter
Colour
Reference standard
NS-EN ISO 7887
Internal method identity
34
Comment
Method C. Automated method.
Object
Clean water and swiming pool water
Parameter
Alkalinity
Reference standard
Internal method
Internal method identity
11
Comment
Method based on withdrawn standard NS 4754 (automated potentiometric titration)
Object
Clean water and pool water
Parameter
Ca Mg
Reference standard
Internal method
Internal method identity
50 51
Comment
AAS-flamme. Method based on NS-EN ISO 7980
Object
Clean water and pool water
Parameter
Total hardness
Reference standard
Internal method
Internal method identity
49
Comment
Method based on calculation from method 50 (Ca) and method 51 (Mg)
Object
Clean water and pool water
Parameter
COD- Mn
Reference standard
Internal method
Internal method identity
06
Comment
Method based on NS-EN ISO 8467 (1995)
Object
Pure water og pool water
Parameter
pH
Reference standard
NS-EN ISO 10523
Internal method identity
34
Comment
Automated method.
Object
Pure water and pool water
Parameter
Turbidity
Reference standard
NS-EN ISO 7027-1
Internal method identity
34
Comment
Nephelometry. Quantitative. Automated method.
Object
Pure water and seawater
Parameter
UV-absorbance and UV transmission
Reference standard
NS 9462
Internal method identity
04
Comment
Object
Clean water and seawater
Parameter
Dissolved oxygen and oxygen saturation
Reference standard
Internal method
Internal method identity
10
Comment
Based on previously NS4734 (1988).
Object
Pure water, Waste water
Parameter
Nitrogen
Reference standard
NS-EN ISO 11905-1
Internal method identity
19
Comment
Method using oxidative digestion with peroxodisulfate
Object
Pure water and pool water
Parameter
Determination of electrical conductivity (ISO 7888:1985)
Reference standard
NS-EN 27888
Internal method identity
34
Comment
Automated method
Object
Pure water, pool water and sea water
Parameter
UV-transmision
Reference standard
Internal method
Internal method identity
34
Comment
Automated method based on NS 9462-1:2006
Object
Clean water, pool water, and wastewater
Parameter
pH
Reference standard
NS-EN ISO 10523
Internal method identity
05
Comment
Manual method.
Object
Clean water, pool water, and seawater
Parameter
Colour
Reference standard
NS-EN ISO 7887
Internal method identity
01
Comment
Method C
Object
Clean water, wastewater, pool water
Parameter
Determination of electrical conductivity (ISO 7888:1985)
Reference standard
NS-EN 27888
Internal method identity
03
Comment
Manuell metode
Object
Seawater
Parameter
pH
Reference standard
Internal method
Internal method identity
07
Comment
Method based on withdrawn NS-EN ISO 4720. Manual method.
Object
Sea water and water with high particle content
Parameter
Turbidity
Reference standard
NS-EN ISO 7027-1
Internal method identity
2
Comment
Nephelometry. Quantitative. Manual method.
Object
Pure water, Waste water, Sea water, Pool water, sludge and sediments
Parameter
Total residue and total fixed residue
Reference standard
NS 4764
Internal method identity
25
Comment
Object
Sludge and compost
Parameter
Glow loss
Reference standard
Internal method
Internal method identity
25
Comment
Method based on NS 4764 (1980)
Object
Dust fallout
Parameter
Water-insoluble material, gram
Reference standard
Internal method
Internal method identity
38
Comment
Method based on NS:4852:2010
Object
Dust fallout
Parameter
Water-insoluble material i g/m2 and 30 days
Reference standard
Internal method
Internal method identity
38
Comment
Method based on NS:4852:2010
Object
Water
Parameter
Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
Reference standard
NS-EN ISO 5815-1
Internal method identity
37
Comment
Oxigen determination according to NS-EN ISO 5814: 2012
P16 Microbiological analysis
Object
Parameter
Reference standard
Internal method identity
Comment
Object
All types of water
Parameter
Clostridium perfringens
Reference standard
NS-EN ISO 14189
Internal method identity
190
Comment
Object
All types of water and enviroment sample
Parameter
Enumeration of Legionella
Reference standard
NS-EN ISO 11731
Internal method identity
181
Comment
Object
Fresh and frozen seafood
Parameter
Coliform bacteria
Reference standard
NMKL 96
Internal method identity
114
Comment
ß-glucuronidase positive E. coli in shell-fish (point 8.2.4) is not included in the akkreditetion scope.
Object
Fresh and frozen seafood
Parameter
Thermotolerant coliform bacteria and E. coli
Reference standard
NMKL 96
Internal method identity
115
Comment
ß-glucuronidase positive E. coli i shell animals (point 8.2.4) is not included in the accredited scope.
Object
Fish and fish products
Parameter
Determination of aerobic mesophiles bacteria, 20°C.
Reference standard
Internal method
Internal method identity
199
Comment
Based on Afnor BIO 12/35-05/13. 20°C (TEMPO® AC)
Object
Fish and fish products
Parameter
Aerobic count and specific spoilage organisms
Reference standard
NMKL 184
Internal method identity
113
Comment
Aerobic count of Long & Hammar Agar (points 8.2.2, 8.3.2 og 8.4.2) is not includeded in the accredited scope
Object
Feed and fish meal
Parameter
Aerobic microorganisms
Reference standard
Internal method
Internal method identity
146
Comment
Based on AFNOR 3M 01/01-09/89.
Object
Foods
Parameter
Pathogenic Vibrio species
Reference standard
NMKL 156
Internal method identity
187
Comment
Qualitative analysis
Object
Foods
Parameter
Anaerobic sulphite-reducing bacteria
Reference standard
NMKL 56
Internal method identity
174
Comment
Determintaion of spores (point 11.3) and verification (point 11.6) is not included in the accredited scope.
Object
Foods
Parameter
Enumeration of aerobic microorganisms
Reference standard
NMKL 86
Internal method identity
107
Comment
At 37°C, 30°C, 25°C, 20°C, 17/7°C or 6,5°C
Object
Foods
Parameter
Enumeration of Enterobacteriaceae
Reference standard
AFNOR BIO 12/21-12/06
Internal method identity
192
Comment
MPN-method (TEMPO® EB)
Object
Food
Parameter
Enumeration of coliforme bacteria
Reference standard
AOAC RI License No 060702
Internal method identity
193
Comment
MPN-method (TEMPO® CC)
Object
Food
Parameter
Determination of viable aerobic mesophilic flora
Reference standard
AFNOR BIO 12/35-05/13
Internal method identity
191
Comment
MPN-method 30°C (TEMPO® AC)
Object
Food
Parameter
Coagulase positive staphylococci
Reference standard
AFNOR BKR 23/10-12/15
Internal method identity
189
Comment
Object
Foods
Parameter
Determination of presumptive Bacillus cereus
Reference standard
NMKL 67
Internal method identity
104
Comment
Quantitative plate method
Object
Food
Parameter
Listeria monocytogenes
Reference standard
AFNOR BRD 07/05- 09/01
Internal method identity
178
Comment
Object
Foods and feeds
Parameter
Enumeration of Escherichia coli
Reference standard
AFNOR BIO 12/13-02/05
Internal method identity
194
Comment
MPN-method (TEMPO® EC)
Object
Foods and feeds
Parameter
Enumeration of coagulase-positive staphylococci
Reference standard
AFNOR BIO 12/28-04/10
Internal method identity
195
Comment
MPN-method (TEMPO® STA)
Object
Food and feeds
Parameter
Determination og Bacillus cereus
Reference standard
AOAC RI License No 071401
Internal method identity
197
Comment
MPN-method (TEMPO® BC)
Object
Foods and feed
Parameter
Enumeration of coliform bacteria
Reference standard
NMKL 44
Internal method identity
102
Comment
Object
Foods and feed
Parameter
Enumeration of thermotolerant coliform bacteria and Escherichia coli
Reference standard
NMKL 125
Internal method identity
110
Comment
Object
Foods and feed
Parameter
Enumeration of Enterococcus
Reference standard
NMKL 68
Internal method identity
105
Comment
Object
Foods and feed
Parameter
Enumeration of Enterobacteriaceae
Reference standard
NMKL 144
Internal method identity
117
Comment
Object
Food, feed and environmental samples
Parameter
Clostridium perfringens
Reference standard
NMKL 95
Internal method identity
109
Comment
Object
Foods, feed and environment samples
Parameter
Enterobacteriaceae
Reference standard
AFNOR 3M 01/06-09/97
Internal method identity
151
Comment
Object
Foods exept dairy products and raw shellfish
Parameter
Aerobic microorganisms (plate count)
Reference standard
AFNOR 3M 01/01-09/89
Internal method identity
146
Comment
Object
Pure water and swiming pool water
Parameter
Escherichia coli and coliform bacteria
Reference standard
NS-EN ISO 9308-1/A1
Internal method identity
168
Comment
Membrane filtration.
Object
Clean water and swing pool water
Parameter
Pseudomonas aeruginosa
Reference standard
Internal method
Internal method identity
169
Comment
Bacteriology. Method based on NS-EN ISO 16266:2008
Object
Clean water and seawater
Parameter
Thermotolerant coliform bacteria and presumptive E.coli
Reference standard
NS 4792
Internal method identity
121
Comment
Object
Clean water, wastewater and seawater
Parameter
Culturable micro-organisms (Kimtall)
Reference standard
Internal method
Internal method identity
123
Comment
At 20°C. Based on NS 4791 (1990).
Object
Clean water, pool water and waste water
Parameter
Culturable micro-organisms
Reference standard
NS-EN ISO 6222
Internal method identity
143
Comment
At 22°C and 37°C.
Object
Clean water, swimming pool water, and seawater
Parameter
Detection and enumeration of intestinal enterococci
Reference standard
ISO 7899-2
Internal method identity
167
Comment
Object
Seawater
Parameter
E.coli and coliform bacteria
Reference standard
Internal method
Internal method identity
168
Comment
Based on NS-EN ISO 9308-1/A1:2017
Object
Water
Parameter
Enumeration of Legionella pneumophila
Reference standard
Afnor IDX 33/06-06/19
Internal method identity
198
Comment
Legiolert, MPN method
P24 Molecular biology
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Food and environmental samples
Parameter
Listeria monocytogenes
Reference standard
AFNOR BRD 07/10-04/05
Internal method identity
177
Comment
PCR
Object
Food, animal feed and environmental samples
Parameter
Salmonella spp
Reference standard
AFNOR BRD 07/06-07/04
Internal method identity
176
Comment
PCR
P31 Flexible accreditation
Object
Parameter
Reference standard
Internal method identity
Comment
Object
P12 - water, food, sludge, compost and dust fallout
Parameter
Inorganic parameters, analytical parameters
Reference standard
Internal method
Internal method identity
Internal method P.22, ID log P.S.29. Measurement principle/analysis platform accredited under chemical analysis.
Comment
The flexibility is limited to the use of methods validated by a third party.
Object
P16 - water, food, feed and enviroment sample
Parameter
Bacteria
Reference standard
Internal method
Internal method identity
Internal method P.22, ID log P.S.29. Measurement principle/analysis platform accredited under microbiological analysis
Comment
Flexibility is limited to the use of methods valided by a third party.
Object
P 24 - food, feed and enviroment sample
Parameter
Bacteria
Reference standard
Internal method
Internal method identity
Internal method P.22, ID log P.S.29. Measurement principle/analysis platform (PCR) accredited under molecular biology.
Comment
Flexibility is limited to the use of methods valided by a third party.
The administrative / geographical unit:
Mjølanodden renseanlegg
Mjølanveien 33
8622 Mo i Rana



Permanent facility
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
Sampling in permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
The administrative / geographical unit:
Mosjøen renseanlegg
Dolstadgata 5
8663 Mosjøen



Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Intern metode
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
The administrative / geographical unit:
Mørkvedbukta renseanlegg
Mørkvedbukta 42
8020 Bodø



Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
The administrative / geographical unit:
Narvik renseanlegg
Standveien 63
8517 Narvik



Permanent facility
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
Sampling in permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
The administrative / geographical unit:
Skanseodden renseanlegg
Båtstøveien 3
8070 Bodø



Permanent facility
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes
Sampling in permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
The administrative / geographical unit:
Stokkvika renseanlegg
Alstadveien 19,
8079 Bodø



Permanent facility
P3001 Sampling waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Samples for chemical analysis
Reference standard
Internal method
Internal method identity
A.M.1
Comment
Method based on automatic sampling of quantity-proportional samples from open water systems
P3099 Flow measurement of waste water
Object
Parameter
Reference standard
Internal method identity
Comment
Object
Waste water
Parameter
Water flow in wastewater treatment plants based on water velocity
Reference standard
Internal method
Internal method identity
A.M.2
Comment
Electromagnetic measurement in closed pipes